Aseguramiento de la trazabilidad del proceso y validación de punto de rocío al agua para despacho de gas a gasoducto de una Planta Deshidratadora de Gas

Show simple item record

dc.contributor.advisor Ruiz, Flavia es_ES
dc.coverage.spatial Cuenca Neuquina ARG es_ES
dc.creator Soto Palomino, Adriana
dc.creator Flores Soliz, Liliana
dc.date 2024-09-03
dc.date.accessioned 2024-09-06T13:49:07Z
dc.date.available 2024-09-06T13:49:07Z
dc.identifier.uri http://rdi.uncoma.edu.ar/handle/uncomaid/18124
dc.description.abstract En la producción de pozos de gas, el gas producido viene saturado en agua, siendo este uno de los contaminantes más comunes que puede acarrear problemas en los procesos posteriores, como en el procesamiento para cumplir con especificación de transporte. La norma NAG - 602/19 (Norma de calidad de gas natural en vigencia, pero no reglamentada como adaptación de la ENARGAS N° 259/08) establece los requisitos de calidad para el gas de transporte. El presente proyecto integrador profesional propone una idea de mejora de los sistemas de monitoreo, enfocado para uno de los varios parámetros que se debe tener en cuenta en la calidad del gas procesado, el cual es el contenido de vapor de agua. En la industria existen varios sistemas de monitoreo, como los instrumentos en línea ‘higrómetro’ ó mediciones puntuales con el Bureau of Mines; si bien los dos miden el punto de rocío al agua, la tecnología empleada es distinta. En este caso se trabajará con el higrómetro con el cual se propone ratificar los valores medidos de forma de incorporándolos como una variable más a obtener en pantalla. El contenido de vapor de agua en el gas de venta, que es obtenido por el higrómetro puede verse afectado con desvíos en el proceso ó por falla de dicho instrumento. Para resolver la mencionada situación se propone incorporar una formula semiempírica basada en Mcketta-Wehe al sistema de adquisición de datos que calcularía el valor esperado según parámetros del proceso y compararía con el valor medido, dando la posibilidad de corroborar la medición de dicho instrumento y automatizar la validación del dato. Asimismo, se pretende predecir desvíos tempranos en el proceso de deshidratación del gas si se demuestra que el higrómetro no presenta alguna falla en la medición. El desarrollo de la propuesta se hará con datos reales de una instalación en servicio: “Planta Deshidratadora de gas con Trietilenglicol”, donde en dicha planta se acondiciona el gas saturado en agua. es_ES
dc.description.abstract In the production of gas wells, the gas produced is saturated with water, this being one of the most common contaminants that can cause problems in subsequent processes, such as processing to comply with transportation specifications. The NAG standard - 602/19 (Natural gas quality standard in force, but not regulated as an adaptation of ENARGAS No. 259/08) establishes the quality requirements for transport gas. This professional integrative project proposes an idea to improve monitoring systems, focused on one of the several parameters that must be taken into account in the quality of the processed gas, which is the water vapor content. In the industry there are several monitoring systems, such as online 'hygrometer' instruments or spot measurements with the Bureau of Mines; Although both measure the dew point of water, the technology used is different. In this case we will work with the hygrometer with which it is proposed to ratify the measured values by incorporating them as another variable to obtain on the screen. The water vapor content in the sales gas, which is obtained by the hygrometer, may be affected by deviations in the process or by failure of said instrument. To resolve the aforementioned situation, it is proposed to incorporate a semi-empirical formula based on Mcketta-Wehe to the data acquisition system that would calculate the expected value according to process parameters and compare it with the measured value, giving the possibility of corroborating the measurement of said instrument and automating data validation. Likewise, it is intended to predict early deviations in the gas dehydration process if it is demonstrated that the hygrometer does not present any measurement failure. The development of the proposal will be done with real data from a facility in service: “Gas Dehydration Plant with Triethylene Glycol”, where the gas saturated in water is conditioned in said plant. es_ES
dc.format application/pdf es_ES
dc.language spa es_ES
dc.publisher Universidad Nacional del Comahue. Facultad de Ingeniería. Departamento de Geología y Petróleo es_ES
dc.rights Atribución-NoComercial-CompartirIgual 2.5 Argentina es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ es_ES
dc.subject Deshidratación de gas es_ES
dc.subject Punto de rocío al agua es_ES
dc.subject Sistemas de monitoreo es_ES
dc.subject.other Ciencias Aplicadas es_ES
dc.title Aseguramiento de la trazabilidad del proceso y validación de punto de rocío al agua para despacho de gas a gasoducto de una Planta Deshidratadora de Gas es_ES
dc.type trabajo final de grado es
dc.type bachelorThesis eu
dc.type acceptedVersion eu
unco.tesis.grado Ingeniera en Petróleo es_ES
dc.description.fil Fil: Soto Palomino, Adriana. Universidad Nacional del Comahue. Facultad de Ingeniería; Argentina. es_ES
dc.description.fil Fil: Flores Soliz, Liliana. Universidad Nacional del Comahue. Facultad de Ingeniería; Argentina. es_ES
dc.cole Trabajos Finales es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial-CompartirIgual 2.5 Argentina Except where otherwise noted, this item's license is described as Atribución-NoComercial-CompartirIgual 2.5 Argentina

Search RDI


Browse

My Account

Statistics